CapillaryABG™

CapillaryABG™

No guesswork. No pain. Just a smooth, confident arterial draw.
Confidence from first flash to final result

CapillaryABG™ Standard
图片名称

Compatible with most blood gas analyzers that accept capillary sample.

图片名称

Small sample volume of ~240 μL

15IU/ml lyophilized balanced heparin is coated

CapillaryABG UCAREFLOW™
图片名称

25 Gauge needle reduces trauma and risk of hematoma

图片名称

The analyzer can only aspirate blood samples after removing the flow-plug before testing

图片名称

The flow-valve stops the blood flowing into the capillary when it's filled

图片名称

Small sample volume of only 320 μl

CapillaryABG iCAREFLOW™
图片名称

Compatible with mostblood qas analyzersthat accept capillary sample

图片名称

Small sample volumeof only 240 μL

图片名称

The flow-valve stops the blood flowing into the capillary

图片名称

The analyzer can only aspirate blood samples after removing the flow-plug before testing

Three Models, One Capillary Core

Choose the configuration that fits your workflow – from basic to fully featured.

 

 

CapillaryABG™ Standard

Simple · Economical · Core capillary benefits


No flow‑valve, no vent – but same micro‑volume, lyophilized heparin, and fixed capillary design. Cost‑effective for high‑volume routine use.

 

 

UCARE‑FLOW™

Flagship · Flow‑valve · Direct analyzer


Integrated flow‑valve and removable flow‑plug. Automatic stop, direct aspiration. Global exclusive.

 

 

 

 

iCARE‑FLOW™

Straight capillary · Flow‑valve · Flexible


Same flow‑valve technology, straight capillary design for maximum flexibility. Use directly with any analyzer’s capillary sampling mode or load onto test cards (e.g., Abbott i‑STAT).

 

Why Capillary?

The superior foundation for blood gas sampling – proven by history and clinical reality.

 

 

The historical truth

Early blood gas analyzers used capillary tubes for calibration – because capillaries deliver bubble‑free, precise volumes. Syringe samples often failed due to air entrapment.

 

Immediate arterial confirmation

Transparent capillary wall gives visible pulsatile “flash” – true arterial blood, not venous. No more blind guessing.

 

 

 

Superior sample integrity

Capillary’s surface‑to‑volume ratio ensures fast, complete mixing with lyophilized heparin. Fixed volume eliminates under‑/over‑fill errors common with syringes.

 

Analyzer‑friendly – no silicone oil

Capillaries have no plunger, therefore no silicone oil – eliminating a major cause of micro‑particle buildup, channel clogging, and electrode drift in blood gas analyzers. This preserves long‑term instrument stability.

 

 

Why Micro‑Volume Matters

 

 

65–150 µL

Analyzer requirement

Most modern blood gas analyzers require only 65–150 µL of whole blood. CapillaryABG™ Series provide ample sample volume without excess.

1.6 mL

Conventional syringe draw

Traditional syringes force 1.6 mL or more – up to 10× the required amount, causing unnecessary blood loss.

 

95 mL/kg

Neonatal blood volume

A 1.6 mL draw from a 2.5 kg neonate represents nearly 2% of total blood volume – a clinically significant iatrogenic loss.

30–50%

Reduction in blood loss

Switching from syringe to capillary micro‑sampling can reduce iatrogenic blood loss by 30–50% in critical care settings.

 

*Iatrogenic anemia is real: Frequent blood draws in ICU patients lead to unnecessary transfusions, increased length of stay, and higher mortality. CapillaryABG™ reduces blood loss without compromising diagnostic quality – especially vital for neonates, children, elderly, and hypotensive patients.

Simplified Workflow


(• UCARE‑FLOW: select syringe aspiration mode • iCARE‑FLOW / Standard: select capillary mode, keep horizontally)

1、Puncture– 25G thin‑wall needle; visual flash confirms arterial entry.

2、Automatic fill– Capillary action draws blood; vent stops at exact volume.

3、Remove flow‑plug(UCARE‑FLOW / iCARE‑FLOW) – sampler ready for analyzer.

4、Direct aspiration– Insert into blood gas analyzer.

 


 

Also compatible with arterial lines:

Use L‑L adapter version (iCARE‑FLOW™ & Standard) or needle‑free model (UCARE‑FLOW™) to connect to stopcocks or indwelling catheters.

CapillaryABG™ Series Means for the Bedside

Clinical impact you can measure – and patients can feel.

 

 

0%

No bubbles, no clots

Hydrophilic capillary coating + lyophilized heparin eliminate air dead space and microclots – preserving anaerobic sample integrity.

25G

Less pain, less trauma

Ultra‑thin‑wall needle (0.5 mm OD) and capillary’s passive fill reduce puncture force and draw time – ideal for low‑pressure, elderly, pediatric, and neonatal patients.

 

240–320 µL

Minimal blood loss

Only a fraction of a milliliter per draw – dramatically reduces iatrogenic anemia risk and preserves patient blood volume.

0

No immediate mixing required

Heparin dissolves instantly; gentle mixing before analysis still recommended, but no aggressive shaking needed – eliminates hemolysis.

 

1

No preset, no guesswork

Capillary fills automatically to fixed volume – operator‑independent, perfect result every time. 

↓ 30%

Better analyzer stability

Clean, clot‑free, bubble‑minimized samples prevent electrode coating and fluid path clogging – reducing downtime and service costs by an estimated 30%.

 

The result: Higher first‑pass success, fewer redraws, reliable lab results, and extended analyzer life.

Product Specifications & Ordering Information

CapillaryABG™ Standard

 

REF* Flow‑valve & plug Safety Connection Gauge Needle Length
150060 Slip 25G (0.5mm) 1" (25mm)
150090 Yes Slip 25G (0.5mm) 1" (25mm)

 

UCARE‑FLOW™ CapillaryABG

Cat. No. Flow‑valve & plug Safety Connection Gauge Needle Length
151030 Yes Slip Needle‑free
151090 Yes Yes Slip 25G (0.5mm) 1" (25mm)

 

iCARE‑FLOW™ CapillaryABG

Cat. No. Flow‑valve & plug Safety Connection Gauge Needle Length
152030 Yes Slip Needle‑free
152090 Yes Yes Slip 25G (0.5mm) 1" (25mm)

 

 Notes: L‑C = Luer to capillary adapter; L‑L = Luer to Luer adapter (capillary connection converted to Luer). Safety versions feature an integrated needle shield with audible lock. For custom configurations or bulk orders, contact info@metermega.com.

Contact with Meteromega

Get the latest news, product updates and clinical insights

Product(s) of Interest (select all that apply)
Security verification
Sign Up Now

By subscribing, you agree to receive occasional email updates from Meteromega.
You can unsubscribe at any time.