Crystal-Hemostop

Crystal-Hemostop

Ball point compression that preserves perfusion, eliminates pain, and achieves 2‑hour evidence‑based hemostasis — from conventional radial to distal radial access.

Fast Hemostasis Starts with One Simple Question: Where to Press?

The answer defines everything. Crystal‑Hemostop™ is built around a single insight: pressure must be applied exactly over the arteriotomy – not the whole wrist.

Focal Spherical Point Compression


The solid elastic sphere concentrates force onto an area smaller than 2 cm² – directly over the radial artery puncture site. This focal pressure seals the vessel wall defect rapidly, without the need for high total force. Unlike flat plates or balloons that compress the entire wrist, the ball leaves surrounding tissues free, preserving antegrade flow and eliminating tourniquet pain.

 

 

Why it works: A sphere is nature’s most efficient force concentrator. MeterOmega’s patented spherical compression element focuses pressure precisely on the subcutaneous arterial breach while the elastic bowl (or water‑drop window) applies gentle counterforce over the skin entry. This dual‑site action ensures that both the superficial wound and the deep arterial puncture are sealed simultaneously, without compromising distal perfusion. Hemostasis is achieved quickly – often within minutes.

 

 

Precision Alignment – The Water‑Drop Window


The unique water-drop shaped window guides placement. Align the drop with the skin puncture site, and the ball automatically centers over the underlying arteriotomy. No guesswork, no Doppler required. The high-transparency material (96% light transmittance) lets you see the puncture site at all times – so you know exactly when bleeding stops.

 

 

 

Advanced Tape Technology


Crystal‑Hemostop™ uses a high‑performance elastic fabric tape. It is breathable, gentle on skin, and hypoallergenic. A proprietary reduced‑adhesion (de‑tacking) treatment ensures the tape holds securely during compression but peels away cleanly without pulling skin or hair – eliminating a major source of patient discomfort and skin injury, especially in elderly or fragile patients.

 

What Focal Compression Delivers

Because pressure is applied only where needed, the benefits extend far beyond hemostasis.

 

 

96%

Light Transmittance

Crystal-clear window for direct visualization – no need to disturb the device to check for bleeding.

 

<30 sec

Application Time

Simple peel‑and‑stick tape system; one application, no staged deflation.

 

 

Significantly reduced

Radial Artery Occlusion

Preserved antegrade flow prevents the ischemia-reperfusion cascade that causes RAO.

 

Nearly eliminated

Tourniquet Pain

No numbness, no tightness – the tape only holds the ball, it does not constrict the wrist.

 

 

2 hours

Evidence‑Based Compression

Maqsood et al. (2023) optimal duration balancing RAO and bleeding – no staged deflation.

 

100%

Clinician Confidence

Transparent window confirms hemostasis; device stays in place without drift.

Why Tourniquet‑Style Compressors Fail

 

 

1

 

Screw‑type plate

Rigid plate compresses radius and ulna, causing pain and nerve compression. Flow often occluded.

1

 

Air‑inflated balloon

Balloon deforms against bone, creating a central void. Over‑inflation required, leading to ischemia.

1

 

Crystal‑Hemostop™

Focal sphere – pressure only on arteriotomy. Flow maintained, patient comfortable.

One Device, Multiple Access Sites


Crystal‑Hemostop™ is not limited to conventional radial artery puncture. Its low-profile, focal compression design works wherever precise pressure is needed:

  • Radial artery
  • Distal radial artery (snuffbox)
  • Forearm artery
  • Upper arm artery
  • Dorsalis pedis artery

Distal radial (snuffbox) hemostasis: Traditional tourniquet-style bands cannot be placed over the anatomical snuffbox. Crystal‑Hemostop™’s focal ball and flexible tape conform to this area, enabling safe and effective hemostasis for the growing practice of distal transradial access.

 

 

Crystal‑Hemostop™ Light


Same ball‑point compression technology, now with a transparent polyurethane (PU) tape. Ultra‑thin, breathable, and waterproof. Ideal for arterial line removal, post‑blood gas puncture, and short‑duration hemostasis in general wards, ICUs, and emergency departments. The clear tape allows full skin visibility and is gentle on fragile skin.

 

 

Product Specifications

Catalog Number Model Tape Type Application Sterility
236560 Standard Elastic fabric Post‑intervention (cath lab) Sterile
236940 Light Polyurethane (PU) transparent Arterial line / post‑puncture Sterile

Key Evidence


  • Maqsood MH, et al. Optimal Hemostatic Band Duration After Transradial Angiography or Intervention. Circ Cardiovasc Interv. 2023;16:e012425. PMID: 36802805.
  • Pancholy S, et al. Prevention of radial artery occlusion‑patent hemostasis evaluation trial (PROPHET). Catheter Cardiovasc Interv. 2008;72(3):335-40. PMID: 18712756.
  • Sanmartin M, et al. Interruption of blood flow during compression and radial artery occlusion. Catheter Cardiovasc Interv. 2007;70(2):185-9. PMID: 17630698.
  • Rathore S, et al. A randomized comparison of TR Band and Radistop hemostatic compression devices. Catheter Cardiovasc Interv. 2010;76(3):330-7. PMID: 20803602.

Contact with Meteromega

Get the latest news, product updates and clinical insights

Product(s) of Interest (select all that apply)
Security verification
Sign Up Now

By subscribing, you agree to receive occasional email updates from Meteromega.
You can unsubscribe at any time.