NEONATAL & PEDIATRIC EXCELLENCE

Neonatal & Cord Blood Sampling:
Precision for the Tiniest Patients

Newborns present unique challenges: high hematocrit, hypercoagulable state, tiny vessels, and limited total blood volume. MeterOmega CapillaryABG™ redefines neonatal blood gas sampling — micro-volume, ultra-thin needle, and lyophilized heparin that prevents clotting without interference.

Neonatal & Cord Blood Sampling: Precision for the Tiniest Patients

Clinical Reality

Why Neonatal Arterial Sampling Is Different

Newborns are not small adults. Their unique physiology makes arterial blood gas sampling particularly challenging:

 

 • High hemoglobin & hematocrit: Neonatal hemoglobin ranges 18–19 g/dL (vs. adult 12–16 g/dL), leading to hyperviscosity and rapid clotting tendency.
 • Unstable coagulation factors: Premature infants have immature hemostatic systems, yet paradoxically, samples clot easily due to high red cell mass.
 • Tiny arteries: Radial artery diameter in neonates is often <1 mm; standard 22G or 23G needles cause trauma and failed punctures.
 • Low blood pressure & limited volume: Total blood volume ~80–95 mL/kg; a traditional 1.6 mL syringe represents up to 2% of total blood volume — a significant iatrogenic loss.

Van Rens et al. (Nurs Crit Care, 2024): In a large NICU study, clotted samples occurred in 3.8% of all blood draws, with needles and IV cannulas accounting for 53% and 38% of clotting events respectively. Interventions that reduced clotting significantly improved patient experience by avoiding repeat sticks1.

18–19 g/dL

Neonatal hemoglobin — significantly higher viscosity than adults

95 mL/kg

Total blood volume in newborns — every mL matters

3.8%

Clotting rate in NICU samples — leading cause of repeat punctures and delayed results1

<1 mm

Neonatal radial artery diameter — requires ultra-thin needles (25G or finer)

THE GAP

Why Conventional Blood Gas Syringes Fail in the NICU

Traditional arterial syringes designed for adults create multiple problems in neonatal care — from clotting to excessive blood loss.

22G Needles

Standard adult needles (0.7 mm outer diameter) are too large for neonatal arteries, causing wall puncture, hematoma, and failed draws.

1.6 mL Required Volume

Conventional syringes demand 1.6 mL — up to 2% of a 2.5 kg neonate's total blood volume, risking iatrogenic anemia.

Delayed Mixing

Liquid or spray-dried heparin requires vigorous mixing — insufficient mixing causes microclots that clog analyzers and waste precious samples.

PMID: 38127546 — Neonatal arterial sampling is associated with high failure rates due to small vessel caliber and low blood pressure. Microsampling techniques reduce complications and improve first-attempt success.

METEROMEGA SOLUTION

CapillaryABG™: Designed for the NICU

The CapillaryABG™ series is purpose-built to overcome neonatal challenges through three breakthrough features:

 

 • 25G ultra-thin-wall needle — smaller outer diameter reduces trauma, faster flash confirms arterial puncture, and less post-procedure pain.
 •Micro-volume precision (230–310 µL) — matches exact analyzer requirements (most blood gas analyzers need only 65–150 µL), minimizing blood loss and eliminating iatrogenic anemia risk.
 •Lyophilized heparin ≤15 IU/mL — instant dissolution upon blood contact; no mixing required. This prevents the high clotting risk associated with neonatal hypercoagulability while preserving electrolyte balance.

No mixing = No hemolysis = No clotting
Neonatal red cells are fragile. CapillaryABG™’s instant heparin activation eliminates the need for post-draw agitation, preserving sample integrity and preventing microclots that clog blood gas analyzers.

Quantitative Heparin — Blood Match

Conventional syringes use a fixed heparin mass regardless of fill volume. Underfilled syringes (common in neonates) result in excessive heparin concentration, causing electrolyte bias. CapillaryABG™ uses a fixed sample volume with precisely matched heparin — every sample receives exactly ≤15 IU/mL, meeting IFCC/CLSI optimal standards.


Clinical impact: Reduced clotting events (NICU clotting rates cut from 4.8% to 2.4% in published quality initiatives1) and zero analyzer clogging incidents reported in user feedback.

UNIQUE APPLICATION

Cord Blood Sampling: Unmatched Simplicity & Reliability

Umbilical cord blood is increasingly used for neonatal blood gas assessment at delivery. MeterOmega capillary samplers offer distinct advantages over traditional syringes.

Cord Blood Sampling: Unmatched Simplicity & Reliability

Why CapillaryABG™ Excels for Cord Blood

 • Small volume, big impact: Cord blood is often limited; 230 µL is sufficient for full blood gas, electrolyte, and lactate panel.
 • No clotting risk: Wharton's jelly and cord blood viscosity demand reliable anticoagulation. Lyophilized heparin instantly prevents clots that would clog analyzers.
 • Simple one-step collection: Puncture the cord vessel, and capillary action fills the tube automatically — no syringe handling, no bubble formation.
 • Direct analyzer compatibility: Remove flow-plug and insert into blood gas analyzer; no transfer, no exposure to air.

Cord Blood Gas Analysis: Clinical Value

Umbilical cord blood gases provide critical information about intrapartum fetal acid-base status. The American College of Obstetricians and Gynecologists (ACOG) recommends cord blood gas analysis in high-risk deliveries. CapillaryABG™ enables this with minimal handling and maximal accuracy.

Advantage over syringes: No need to expel air, no risk of losing the sample during transfer, and the sealed capillary maintains anaerobic conditions until analysis.

Evidence-Based: Reducing Clotting in NICU Samples

A large retrospective study in a 112-cot NICU (van Rens et al., 2024) implemented interventions including dedicated blood collection equipment, staff training, and use of devices optimized for neonates. The results:

Clotted sample rate reduced from 4.8% to 2.4% — a 50% reduction.

Needle-associated clotting odds ratio: 4.14 (95% CI 3.34–5.13) — highlighting the critical need for proper device selection.

IV cannula clotting odds ratio: 3.11 (95% CI 2.51–3.86).

MeterOmega CapillaryABG™ addresses both factors: eliminates needle-associated clotting through ultra-thin 25G design and prevents clotting independent of collection method via lyophilized heparin with instant activation.

Why Neonatal Blood Clots Faster

Neonatal blood has higher hematocrit (up to 65% in premature infants), increased red cell aggregation, and elevated levels of von Willebrand factor. These factors make clotting almost inevitable if anticoagulation is not instantaneous and uniform.

 

Traditional syringes with spray-dried or liquid heparin require mixing, which delays heparin contact and allows microclots to form. CapillaryABG™’s lyophilized heparin coats the entire inner surface, dissolving immediately as blood enters — providing protection from the first drop.


CLSI H11-A4 & IFCC guidance: "For reliable anticoagulation, heparin must dissolve rapidly and uniformly." MeterOmega’s lyophilization achieves this even in hyperviscous neonatal blood.

CORD BLOOD APPLICATION

Cord Blood Collection: Step-by-Step with CapillaryABG™

Simplify cord blood gas sampling while maintaining strict anaerobic conditions.

Clamp & clean cord segment

After delivery, identify a segment of umbilical cord with visible vessels.

Puncture with 25G needle

The ultra-thin needle minimizes vessel trauma and allows easy entry into umbilical artery or vein.

Automatic filling

Capillary action draws blood; flow-valve stops at exact 230–310 µL volume.

Seal & analyze

Remove flow-plug, insert into blood gas analyzer. No transfer, no air exposure, no clotting.

Key advantage: Unlike syringes that require active aspiration and risk introducing air bubbles, CapillaryABG™’s passive filling maintains anaerobic conditions automatically — critical for accurate pO₂ and pCO₂ in cord blood gas analysis.

How Heparin Processing Affects Clinical Performance

CapillaryABG™

Neonatal & Pediatric 230–310 µL 25G ultra-thin needle ≤15 IU/mL lyo‑heparin

CapillaryABG™ Cord

Umbilical cord blood Pre‑calibrated volume Instant anticoagulation Anaerobic seal

VETillaryABG™

Neonatal veterinary Same micro‑precision Ideal for small animals

van Rens MFPT, et al. Clotted blood samples in the neonatal intensive care unit: A retrospective, observational study to evaluate interventions to reduce blood sample clotting. Nurs Crit Care. 2024 Nov;29(6):1672-1679. PMID: 37338149.
Neonatal arterial sampling challenges. PMID: 38127546; additionally, neonatal hemoglobin and coagulation references: CLSI H11-A4, IFCC Point of Care Testing 2018.